Use Low-Impedance Bridges on 4-20mA Current Loop

Texas Instruments

Published Date: 09/27/2000

Description

If you need more transducer excitation current than is available on a standard 4-20mA 2-wire current loop consider a 3-wire transmitter. A 2-wire 4-20mA transmitter uses the same two wires for signal and power. Part of the 4mA minimum loop current is used to power the transmitter circuitry. The remaining current can be used for transducer excitation. In some applications even the entire 4mA is no

Parts

Part Number Name Companion Part
INA114APG4 INA114APG4 Buy Datasheet
INA114AU INA114AU Buy Datasheet
INA114AU/1K INA114AU/1K Buy Datasheet
INA114AU/1KE4 INA114AU/1KE4 Buy Datasheet
INA114AUE4 INA114AUE4 Buy Datasheet
INA114AUG4 INA114AUG4 Buy Datasheet
INA114BP INA114BP Buy Datasheet
INA114BPG4 INA114BPG4 Buy Datasheet
INA114BU INA114BU Buy Datasheet
INA114BU/1K INA114BU/1K Buy Datasheet
INA114BU/1KE4 INA114BU/1KE4 Buy Datasheet
XTR101AG XTR101AG Buy Datasheet
XTR101AU XTR101AU Buy Datasheet
XTR101AU/1K XTR101AU/1K Buy Datasheet
XTR101AU/1KG4 XTR101AU/1KG4 Buy Datasheet
XTR101AUG4 XTR101AUG4 Buy Datasheet
XTR101BG XTR101BG Buy Datasheet
XTR103AP XTR103AP Buy Datasheet
XTR103AP2 XTR103AP2 Buy Datasheet
XTR103AU XTR103AU Datasheet
XTR103AU/1K XTR103AU/1K Datasheet
XTR103BP XTR103BP Datasheet
XTR103BP1 XTR103BP1 Buy Datasheet
XTR103BU XTR103BU Buy Datasheet
XTR103BU/1K XTR103BU/1K Datasheet
XTR110AD XTR110AD Datasheet
XTR110AG XTR110AG Buy Datasheet
XTR110BG XTR110BG Buy Datasheet
XTR110KP XTR110KP Buy Datasheet
XTR110KPG4 XTR110KPG4 Buy Datasheet
XTR110KU XTR110KU Buy Datasheet
XTR110KU/1K XTR110KU/1K Buy Datasheet
XTR110KU/1KG4 XTR110KU/1KG4 Buy Datasheet
XTR110KUG4 XTR110KUG4 Buy Datasheet