985GP 07

Part Number : 985GP 07

Marathon
TERMINAL BLOCK BARRIER 7 POSITION 18-4AWG; No. of Rows:2 Row; No. of Positions:7Positions; Wire Size AWG Min:18AWG; Wire Size AWG Max:4AWG; Pitch Spacing:15.88mm; Rated Current:85A; Rated Voltage:600V; Product Range:- ;RoHS Compliant: Yes

0987-RZ-TC-08

Part Number : 0987-RZ-TC-08

Marathon
TERMINAL BLOCK BARRIER 8 POSITION 24-8AWG; No. of Rows:2 Row; No. of Positions:8Positions; Wire Size AWG Min:24AWG; Wire Size AWG Max:8AWG; Pitch Spacing:12.1mm; Rated Current:50A; Rated Voltage:600V; Product Range:987 Series ;RoHS Compliant: Yes

208

Part Number : 208

Marathon
TERMINAL BLOCK BARRIER 8 POSITION 22-12AWG; No. of Rows:2 Row; No. of Positions:8Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:12AWG; Pitch Spacing:11.1mm; Rated Current:30A; Rated Voltage:600V; Product Range:-

CH1322

Part Number : CH1322

Marathon
HINGED COVER THERMOPLASTIC; Accessory Type:Hinged Cover; For Use With:Power Blocks; Connector Body Material:Thermoplastic Body; Product Range:-; Enclosure Material:Plastic ;RoHS Compliant: Yes

600RJS-22

Part Number : 600RJS-22

Marathon
TERMINAL BLOCK JUMPER 22WAY 9.5MM; Accessory Type:Jumper; For Use With:Single and Double row flat mount thermoset terminal blocks; No. of Positions:22Positions; Pitch Spacing:9.5mm; Product Range:-; Body Material:Brass

670A GP 03

Part Number : 670A GP 03

Marathon
TERMINAL BLOCK BARRIER 3 POSITION 22-12AWG; No. of Rows:2 Row; No. of Positions:3Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:12AWG; Pitch Spacing:9.53mm; Rated Current:20A; Rated Voltage:250V; Product Range:- ;RoHS Compliant: Yes

600RJ-04

Part Number : 600RJ-04

Marathon
TERMINAL BLOCK JUMPER 4WAY 9.5MM; Accessory Type:Jumper; For Use With:Double Row Terminal Blocks; No. of Positions:4Positions; Pitch Spacing:9.5mm; Product Range:- ;RoHS Compliant: Yes

EPBAD24

Part Number : EPBAD24

Marathon
ENCLOSED POWER BLOCK 4 POSITION 14-2AWG; Rated Current:115A; Rated Voltage:600V; No. of Poles:5 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wire Size Max:2AWG; Load Side Wire Size Max:10AWG

104

Part Number : 104

Marathon
TERMINAL BLOCK BARRIER 4 POSITION 22-12AWG; No. of Rows:2 Row; No. of Positions:4Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:12AWG; Pitch Spacing:9.5mm; Rated Current:20A; Rated Voltage:250V; Product Range:- ;RoHS Compliant: Yes

1504SC

Part Number : 1504SC

Marathon
TERMINAL BLOCK BARRIER 4 POSITION 16-10AWG; No. of Rows:2 Row; No. of Positions:4Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:10AWG; Pitch Spacing:15.88mm; Rated Current:75A; Rated Voltage:600V; Product Range:-

1508SC

Part Number : 1508SC

Marathon
TERMINAL BLOCK BARRIER 8 POSITION 10-16AWG; No. of Rows:2 Row; No. of Positions:8Positions; Wire Size AWG Min:16AWG; Wire Size AWG Max:10AWG; Pitch Spacing:15.88mm; Rated Current:30A; Rated Voltage:600V; Product Range:-

1512SC

Part Number : 1512SC

Marathon
TERMINAL BLOCK BARRIER 12 POSITION 16-10AWG; No. of Rows:2 Row; No. of Positions:12Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:10AWG; Pitch Spacing:15.88mm; Rated Current:75A; Rated Voltage:600V; Product Range:-

670A-RZ-04

Part Number : 670A-RZ-04

Marathon
TERMINAL BLOCK BARRIER 4 POSITION 22-12AWG; No. of Rows:2 Row; No. of Positions:4Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:12AWG; Pitch Spacing:9.5mm; Rated Current:20A; Rated Voltage:250V; Product Range:-

1612STD

Part Number : 1612STD

Marathon
TERMINAL BLOCK BARRIER 12 POSITION 16-10AWG; No. of Rows:2 Row; No. of Positions:12Positions; Wire Size AWG Min:22AWG; Wire Size AWG Max:10AWG; Pitch Spacing:16.67mm; Rated Current:75A; Rated Voltage:600V; Product Range:-

600RJ 06

Part Number : 600RJ 06

Marathon
TERMINAL BLOCK JUMPER 6WAY 9.5MM; Accessory Type:Jumper; For Use With:670A RZ terminal block; No. of Positions:6Positions; Pitch Spacing:9.5mm; Product Range:-

R30A2S

Part Number : R30A2S

Marathon
FUSE HOLDER 19/16 X 2"; Fuse Holder Type:Cartridge Fuse Holder; Product Range:-; Fuse Current:30A; Voltage Rating VAC:250V; Voltage Rating VDC:250V; Fuse Size Held:9/16" x 2"; No. of Fuses:2Fuses; Holder Terminals:Screw

EPBAD42

Part Number : EPBAD42

Marathon
ENCLOSED POWER DISTRIBUTION BLOCK 1 POSITION 14-3/0AWG; No. of Poles:2 Pole; Rated Voltage:600V; Rated Current:200A; Line Side Connection Method:Screw; Line Side Connections Per Pole:1; Line Side Wire Size Max:000AWG; Colour:Grey

EPBAP42

Part Number : EPBAP42

Marathon
ENCLOSED POWER DISTRIBUTION BLOCK 1 POSITION 14-3/0AWG; Rated Current:200A; Rated Voltage:600V; No. of Poles:2 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wire Size Max:000AWG; Colour:Grey

EPBCD42

Part Number : EPBCD42

Marathon
ENCLOSED POWER DISTRIBUTION BLOCK 1 POSITION 14-3/0AWG; No. of Poles:2; Rated Voltage:600V; Rated Current:200A; Line Side Connection Method:Screw; Line Side Connections Per Pole:1; Line Side Wire Size Max:000AWG; Colour:Grey

EPBCP45

Part Number : EPBCP45

Marathon
ENCLOSED POWER DISTRIBUTION BLOCK 4 POSITION 14-3/0AWG; Rated Current:200A; Rated Voltage:600V; No. of Poles:5 Pole; Line Side Connections Per Pole:1; Line Side Connection Method:Screw; Line Side Wire Size Max:000AWG; Colour:Grey

Displaying 1321 - 1340 of 4226

Latest Parts

IN STOCK 1481
Buy

ASX00049

Arduino

* $44.83 - * $50.26

IN STOCK 2760
Buy

1687559

Phoenix Contact Ltd

[no prices available]

IN STOCK 3
Buy

Reference Designs

RD006

Wurth Elektronik

RD006 - 3 W Dual-output isolated auxiliary supply for communication interfaces and measurement systems

CN0583

Analog Devices Inc.

Multistandard Micropower Verified Smoke Detection System-on-Module

Technical Resources

EVALUATION KITS

EVAL-AD7124-8SDZ

Analog Devices Inc.

$0.00 - * $70.54

IN STOCK 792
Buy
View All